The LI-COR LI-7815 CO2/H2Trace Gas Analyzer provides exceptionally stable and precise measurements for long-term atmospheric monitoring measurements. CO2 measurements drift less than 0.2 ppm per 24-hour period with 0.04 ppm precision (1σ, with 5-second averaging) at 400 ppm CO2 in dry air at STP.

LI-7815 Specifications

General

  • Measurement Technique: OF-CEAS (Optical Feedback-Cavity Enhanced Absorption Spectroscopy)
  • Measurement Rate: 1 sample per second (1 Hz)
  • Optical Cavity Volume: 6.41 cm3
  • Flow Rate: 250 sccm (nominally)
  • Total Weight: 10.5 kg (including batteries)
  • Case Dimensions: 51 cm L x 33 cm W x 18 cm H
  • Operating Temperature Range: -25 °C to 45 °C (without solar load, under normal operating conditions)
  • Operating Humidity Range: 0 to 85% RH (non-condensing, without solar load, under normal operating conditions)
  • Sample Line Humidity Range: 0 to 99.9% non-condensing
  • Operating Pressure Range: 70 to 110 kPa
  • Connectivity: Ethernet, Wi-Fi (not available in some countries)
  • Wi-Fi Compatibility: 2.4 GHz, 802.11 a/b/g/n/ac
  • Power Consumption:
    • Steady State Operation: 22 W at 25 °C
    • Warmup (10.5 to 33 VDC power supply, pins 3 and 4): Up to 90 W
    • Warmup (Universal power supply or 24VDC power supply, pins 1 and 5): Up to 140 W with batteries charging
  • Power Supply: Universal Power Adapter (Input: 100 to 240 VAC, 50-60 Hz; Output: 24 VDC)
  • Battery Life: 8 hours typical with 2 batteries

CO2/H2O Measurements

  • Response Time (T10-T90): CO2 ≤ 2 seconds, 0 to 400 ppm

CO2 Measurements

  • Measurement Range: 1 to 10,000 ppm
  • Precision (1σ):
    • 0.10 ppm at 400 ppm with 1 second averaging
    • 0.04 ppm at 400 ppm with 5 second averaging
  • Maximum Drift: < 0.2 ppm per 24-hour period

H2Measurements

  • Measurement Range: 100 to 60,000 ppm
  • Precision (1σ):
    • 45 ppm at 10,000 ppm with 1 second averaging
    • 20 ppm at 10,000 ppm with 5 second averaging
Imagen de LI-7815 CO2/H2O Trace Gas Analyzer

Contact us

If you are thinking of carrying out a project, would like to purchase any instrumentation type or would like more information about DILUS services, please leave your contact information. The team will contact you as soon as possible.LI-7815 CO2/H2O Trace Gas Analyzer, leave your details. The team will contact you as soon as possible.



    Controller: DILUS INSTRUMENTACIÓN Y SISTEMAS S.A.
    Purpose: Collection of personal data to be able to respond to your request
    Legal Basis: Consent of the data subject
    Recipients: No data will be transferred to third parties, except when legally required and except to entities collaborating with DILUS INSTRUMENTACIÓN Y SISTEMAS S.A. for the provision of services and the correct management of the entity. In such cases, data will only be used for purposes and uses strictly necessary for the development of their activity and for which their services were required, and they may not use the data for any other purpose
    Rights: Access, rectify, or delete data, as well as other rights, as explained in the additional information in the privacy policy