Spot Measurements

LI-7810 CH4/CO2/H2O Trace Gas Analyzer

Add to budget
Imagen de: LI-7810 CH4/CO2/H2O Trace Gas Analyzer

When methane matters most

The LI-COR LI-7810 CH4/CO2/H2Trace Gas Analyzer provides exceptionally stable and precise methane measurements in a design that is both surprisingly portable and affordable. CH4 measurements drift less than 1 ppb per 24-hour period with 0.25 ppb precision (1σ, with 5-second averaging) at 2000 ppb CH4 in dry air at STP.

Achieve the long-term stability and precision needed for atmospheric monitoring, with the flexibility of design for deployments in mobile monitoring or soil flux research.

LI-7810 Specifications

General

  • Measurement Technique: OF-CEAS (Optical Feedback-Cavity Enhanced Absorption Spectroscopy)
  • Measurement Rate: 1 sample per second (1 Hz)
  • Optical Cavity Volume: 6.41 cm3
  • Flow Rate: 250 sccm (nominally)
  • Total Weight: 10.5 kg (including batteries)
  • Case Dimensions: 51 cm L x 33 cm W x 18 cm H
  • Operating Temperature Range: –25 °C to 45 °C (without solar load, under normal operating conditions)
  • Operating Humidity Range: 0 to 85% RH (non-condensing, without solar load, under normal operating conditions)
  • Sample Line Humidity Range: 0 to 99.9% non-condensing
  • Operating Pressure Range: 70 to 110 kPa
  • Connectivity: Ethernet, Wi-Fi (not available in some countries)
  • Wi-Fi Compatibility: 2.4 GHz, 802.11 a/b/g/n/ac
  • Power Consumption:
    • Steady State Operation: 22 W at 25 °C
    • Warmup (10.5 to 33 VDC power supply, pins 3 and 4): Up to 90 W
    • Warmup (Universal power supply or 24 VDC power supply, pins 1 and 5): Up to 140 W with batteries charging
  • Power Supply: Universal Power Adapter (Input: 100 to 240 VAC, 50-60 Hz; Output: 24 VDC)
  • Battery Life: 8 hours typical with 2 batteries

CH4/CO2/H2O Measurements

  • Response Time (T10-T90): CH4 ≤ 2 seconds, 0 to 2 ppm

CH4 Measurements

  • Measurement Range: 0.1 to 100 ppm
  • Precision (1σ):
    • 0.60 ppb at 2 ppm with 1 second averaging
    • 0.25 ppb at 2 ppm with 5 second averaging
  • Maximum Drift: < 1 ppb per 24-hour period

CO2 Measurements

  • Measurement Range: 1 to 10,000 ppm
  • Precision (1σ):
    • 3.5 ppm at 400 ppm with 1 second averaging
    • 1.5 ppm at 400 ppm with 5 second averaging

H2O Measurements

  • Measurement Range: 100 to 60,000 ppm
  • Precision (1σ):
    • 45 ppm at 10,000 ppm with 1 second averaging
    • 20 ppm at 10,000 ppm with 5 second averaging

Specifications subject to change without notice.

Imagen de LI-7810 CH4/CO2/H2O Trace Gas Analyzer

Contact us

If you are thinking of carrying out a project, would like to purchase any instrumentation type or would like more information about DILUS services, please leave your contact information. The team will contact you as soon as possible.LI-7810 CH4/CO2/H2O Trace Gas Analyzer, leave your details. The team will contact you as soon as possible.



    Controller: DILUS INSTRUMENTACIÓN Y SISTEMAS S.A.
    Purpose: Collection of personal data to be able to respond to your request
    Legal Basis: Consent of the data subject
    Recipients: No data will be transferred to third parties, except when legally required and except to entities collaborating with DILUS INSTRUMENTACIÓN Y SISTEMAS S.A. for the provision of services and the correct management of the entity. In such cases, data will only be used for purposes and uses strictly necessary for the development of their activity and for which their services were required, and they may not use the data for any other purpose
    Rights: Access, rectify, or delete data, as well as other rights, as explained in the additional information in the privacy policy