Tunnel

AIRFLOW MKII

Add to budget
Imagen de: AIRFLOW MKII

Using proven, ultrasound time of flight technology ensures the AIRFLOW MkII provides consistent and accurate measurements. The data provided by the AIRFLOW-MkII can be used as part of an air quality management system within a tunnel or other confined spaces including rail and cable tunnels and mining applications.

The AIRFLOW-MkII has no moving parts and no regular service requirements, making it a truly fit and forget monitor. With industry standard SCADA / PLC interface options, such as Current Outputs, Digital Relays and RS485 (Modbus RTU) the AIRFLOW-MkII is a self-contained, intelligent, tunnel airflow monitor.

Specification

Airflow Measurement

No. Parameter Units Min Max Comment
1 Measuring Principle Ultrasonic transit time
2 Measurement Range m/s
mph
-60
-134
+60
+134
User selectable
(also available as ft/min or kph)
3 Resolution m/s 0.01 Display resolution
4 Accuracy m/s
%
-0.1
-2
+0.1
+2
Relative to reading
5 Damping seconds 1 100 Response time ~3x damping

Temperature Measurement
(AIRFLOW-T only)

No. Parameter Units Min Max Comment
6 Measuring Principle RTD
7 Measurement Range °C -20 +70 User selectable (also available °F)
8 Resolution °C 0.1 Display resolution
9 Accuracy °C -0.5 +0.5
10 Damping Seconds 1 100 User selectable
(response time~3x damping)

Power

No. Parameter Units Min Max Comment
11 Voltage Vdc +24
12 Voltage Tolerance % -10 +10
13 Nominal Current Consumption mA 200
14 Power Up Current Consumption mA 200

Interface Options

No. Parameter Units Min Max Comment
15 Serial Outputs Modbus RTU via RS485
External USB
16 Analogue Outputs (two or four) mA 0 /2 /4 20 Isolated and scalable (user selected)
17 Digital Relay Contacts (five) A 0 3 @30Vdc (signal level and data vaild)

Physical

No. Parameter Units Min Max Comment
18 Ingress Protection IP67
19 Operating Temperature °C -30 +70
20 Operating Humidity % 100
21 Operating Pressure hPa 600 1300
22 Materials
Enclosure
Transceiver

AISI/SAE 316L Stainless steel
Flame retardant UL rated polycarbonate
23 Dimensions mm 220 x 240 x 160
24 Weight kg 3.5
25 Regulatory Compliance 2014/20/EU (Electromagnetic Radiation)
2014/35/EU (Low Voltage)
26 Design Life Years 20
27 MTBF Years >20
28 Warranty Months 24 Return to base warranty. Extensions available
Imagen de AIRFLOW MKII
Imagen de AIRFLOW MKII
Imagen de AIRFLOW MKII
Imagen de AIRFLOW MKII

Contact us

If you are thinking of carrying out a project, would like to purchase any instrumentation type or would like more information about DILUS services, please leave your contact information. The team will contact you as soon as possible.AIRFLOW MKII, leave your details. The team will contact you as soon as possible.



    Controller: DILUS INSTRUMENTACIÓN Y SISTEMAS S.A.
    Purpose: Collection of personal data to be able to respond to your request
    Legal Basis: Consent of the data subject
    Recipients: No data will be transferred to third parties, except when legally required and except to entities collaborating with DILUS INSTRUMENTACIÓN Y SISTEMAS S.A. for the provision of services and the correct management of the entity. In such cases, data will only be used for purposes and uses strictly necessary for the development of their activity and for which their services were required, and they may not use the data for any other purpose
    Rights: Access, rectify, or delete data, as well as other rights, as explained in the additional information in the privacy policy