The VS2k visibility sensor measures visibility up to 2000m, ideal for road traffic applications on motorways, highways or bridges. A calibration device is available (optional).
The VS2k-UMB is configured via the software UMB Config Tool:
Reading / Changing of the current configuration,
calibration,
polling of the current measurement values,
the software allows configurations to be loaded and stored.
The measurement data is available for further processing in the form of the standard protocol Lufft UMB. ASD = Active Spider Defense: The built-in vibrating motor ensures at irregular intervals that the VS2k visibility sensor is not so prone to spiders. The construction of VS2k also reduces the frequency of maintenance.
General | |
Dimensions | 500x230x80mm |
Weight | Approx. 4kg |
Protection type | IP66 |
Interfaces | RS485 (2-wire, half duplex); Analogue output (4 – 20mA) |
Value update | 1/minute |
Included in delivery | Connection cable |
Cable length | 10m |
Storage conditions | |
Admissible storage temperature | -40…70°C |
Operating rel. humidity | 0…100% RH (non condensing), 0 … 98% (inside packaging) |
Operating conditions | |
Operating temperature | -40…60°C |
Operating rel. humidity | 0…100% RH |
Power supply | 20…30VDC; typical 24VDC |
Power consumption | < 200mA (motor running and current outputs active), about 100mA in normal mode and RS485 output |
Power consumption | 3W (typical), 10W (max.) |
Protection class | III (SELV) |
Visibility | |
Principle | 45° forward scattering |
Measuring range | 10 … 2000 m |
Unit | m |
Accuracy | ±10% visibility |
Documentos
Contáctenos
Si está pensando en llevar a cabo un proyecto, desea adquirir instrumentación, quiere más información al respecto de los servicios de DILUS o desea mas información sobre Visibility Sensor VS2k-UMB, deje sus datos. El equipo se pondrá en contacto con usted a la mayor brevedad posible.