Data logger DLX Met
Añadir al presupuestoPart number: 9.1756.x0.xxx
The instrument is to be operated easily via three keys or via the serial interface COM 1 and USB. A three-line alphanumeric display (LCD) serves as indicator. The instrument is supplied by an integrated 12V-battery, and the operation is completely mains independent thanks to the special low power design with respective solar panel and integrated solar controller. An integrated transformer offers the operation at 115 V / 230 V power supply.
Three serial interfaces COM 1- COM 3 and in addition one USB offer beside the communication also the connection of sensors with respective operation modes (RS232 or RS285).
Specification
Part number: 9.1756.x0.xxx
Analogue data sampling
|
|
A/D – converter
|
24 bit
|
Accuracy
|
±0.1 % of meas. range
|
Precipitation
|
|
Electrical input
|
1 x impulses (0 … 5 V)
1 x status ( 0 … 5 V) |
Resolution
|
0.1 mm
|
Temperature
|
|
Electrical input
|
2 x PT100
|
Measuring range
|
-40 … +70 °C
|
Accuracy
|
±0,1 mK
|
Rel. Humidity
|
|
Electrical input
|
1 x 0 … 1 V
|
Measuring range
|
0 … 100 % rel. h.
|
Accuracy
|
± 0.001% rel. h.
|
Radiation
|
|
Electrical input
|
1 x 0 … 40 mV
|
Accuracy
|
±2.7 W/m² @ 15mW/m² sensitivity
|
Air pressure
|
|
Electrical input
|
0 … 5 V
|
Measuring range
|
configurable 500 … 1200 hPa
|
Accuracy
|
±0.005 hPa
|
Miscellaneous
|
|
Electrical input
|
0 … 20 mA
|
Measuring range
|
0 … 100 %
|
Serial interfaces
|
|
Quantity
|
3
|
Configuration
|
COM1: USB or RS232 or RS485 (Full duplex)
COM2: RS232 or RS485 (Full duplex) COM3: RS485 (Half duplex) |
Supported devices
|
COM2 / COM3 supports:
LPM, US2D, US2D Compact, Clima Sensor US, Sensor interface |
Function
|
COM1: data access
COM2: sensor connection or output of instantaneous data COM3: sensor connection or output of instantaneous data |
Data input analog
|
|
Meas. range
|
skaled to 0 … 100 %
|
Input type
|
0 … 20 mA
|
Data input digital
|
|
Typ
|
1 x wind speed
1 x wind direction (synchron serial) 1 x precipitation counter (0.1 or 0.2 mm) 1 x precipitation status |
Data management
|
|
Measurement cycle
|
1 … 3600 s
|
Memory cycle
|
1 … 60 min
|
Memory capacity
|
2 MByte
|
Number data records
|
61570 (10 channels)
|
Output of archive values
|
serial via COM1 (ASCII – formatted)
Export to SD – card (ASCII – formatted) |
Channel extension
|
|
Sensor interface SIF001
|
6 x Radiation (0 … 20 mV)
2 x Temperature (PT100) |
Sensor interface SIF002
|
1 x 0 … 10 V
2 x 0 … 1 V 3 x Radiation (0 … 20 mV) 3 x Temperature (PT100) |
Sensor interface SIF003
|
2 x 0 … 10 V
2 x Radiation (0 … 40 mV) 2 x 0 … 20 mA 3 x Temperature (PT100) |
Sensor interface SIF004
|
2 x 0 … 10 V
2 x Radiation (0 … 40 mV) 1 x 4 … 20 mA 1 x 0 … 20 mA 3 x Temperature (PT100) |
Operating voltage
|
|
Electronic
|
230 V AC
|
Current consumption
|
max. 1 mA (measmode, display off)
max. 12 mA (measmode, display on) |
Battery connection
|
internal battery 12 V, 6,5Ah
|
Internal battery charger
|
15 … 18 V / max. 20 W
|
General
|
|
Ambient temp.
|
-30 … +60 °C
|
Electr. connection
|
clamp
|
Dosplay
|
LCD-Display 3 x 16 digits
|
Housing
|
stainless steel
|
Protection
|
IP 65
|
Dimension
|
380 x 300 x 155 mm
|
Weight
|
6.5 kg
|
Contáctenos