The measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy. It is especially suited for the measurement of gust- and peak values. The measuring values can be output digitally and/or in analogue form. The serial or analogue output of the data is carried out alternatively as instantaneous value or as gliding mean value with selectable time frame.
If necessary, the sensor arms are automatically heated with critical ambient temperatures.
Specification
Part number: 4.3865.0x.xxx

Wind speed
|
|
Measuring range
|
0 … 75 m/s
|
Resolution
|
0.1 m/s
|
Accuracy
|
±0.1 m/s rms ( < 5 m/s )
±2 % rms ( > 5 m/s ) |
Wind direction
|
|
Measuring range
|
1 or 181 °
|
Virtual temp.
|
|
Measuring range
|
-50 … +80 °C
|
Resolution
|
0.1 K
|
Accuracy
|
±0.5 K
|
Data output digital
|
|
Interface
|
RS485 / RS422
|
Baudrate
|
1200 … 921600 Baud
|
Data values
|
instant. values, average values
|
Output range
|
1 per 10 msec up to
1 per 60 sec |
Status signals
|
heating, distance error
|
Data output analog
|
|
Wind speed
|
0 … 20 mA
4 … 20 mA 0 … 10 V 2 … 10 V |
Stromausgang
|
max. 400 Ω
|
Voltage output
|
min. 4000 Ω
|
Resolution
|
16 bit
|
Operating voltage
|
|
Electronic
|
8 … 42 V DC or
12 … 28 V AC / 2.5 W |
Heating
|
24 V AC/DC, typ 40 W
|
General
|
|
Bus operation
|
up to 98 sensors
|
Electr. connection
|
5 m cable
|
Mounting
|
plate with holes
|
Housing
|
stainless stell (V4A) AiSi316Ti
|
Protection
|
IP 67
|
Dimension
|
424 mm x 287 mm
|
Weight
|
2.5 kg
|

Documents
Contact us
If you are thinking of carrying out a project, would like to purchase any instrumentation type or would like more information about DILUS services, please leave your contact information. The team will contact you as soon as possible.Ultrasonic Anemometer 1D, leave your details. The team will contact you as soon as possible.