Direct Radiation (pyrheliometers)

SHP1 Pyrheliometer

Add to budget
Imagen de: SHP1 Pyrheliometer
  • ISO 9060 Spectrally Flat Class A
  • 2 second response time
  • RS-485 Modbus® RTU
  • 0-1 V or 4-20 mA versions
  • Best temperature correction
  • 5 year warranty 

SHP1 Pyrheliometer

The combination of the CHP1 sensor technology with smart interface advantages makes the SHP1 even better, and with faster response.

The smart interface not only provides versatile outputs, the integrated temperature sensor and digital polynomial functions also provide individual correction for the temperature sensitivity of the detector from -40 °C to +80 °C. The standardised output makes it easy to interchange instruments for recalibration.

SHP1 pyrheliometers have extremely low power consumption so that internal heating does not affect the detector performance. They operate from a wide range of supply voltages, making them ideal for power-critical applications, and the power input is protected against reversed polarity.

Two versions are available, SHP1-V has an analogue output of 0-1 V, SHP1-A is 4-20 mA. Both have a 2-wire RS-485 serial interface with Modbus® RTU protocol that provides a range of instrument status and configuration information, with user-selectable options.

The analogue outputs allow easy connection to virtually any data logger without the need for sensitive mV inputs. Modbus® interfaces directly to PLC and SCADA systems, industrial networks and controllers. A recalibrated instrument keeps the same analogue and digital measurement ranges, saving time by eliminating re-scaling of data collection equipment.

Kipp & Zonen SmartExplorer Windows™ software for instrument configuration, data display and data logging is available at no charge.

For instructions on the installation of the pyrheliometer on the SOLYS2 sun tracker please watch this video.

Specifications

Spectral range (50% points) 200 to 4000 nm
Response time (63%) < 0.7 s
Response time (95%) < 2 s
Zero offset due to temperature change (5K/h) < 1 W/m²
Temperature dependence of sensitivity (-30 ºC to +60 ºC) < 0.5 %
Analogue output (-V version) 0 to 1 V
Analogue output (-A version) 4 to 20 mA
Digital output 2-wire RS-485
Power supply 5 to 30 VDC
Classification to ISO 9060:2018 Spectrally Flat Class A
Imagen de SHP1 Pyrheliometer
Imagen de SHP1 Pyrheliometer
Imagen de SHP1 Pyrheliometer
Imagen de SHP1 Pyrheliometer
Imagen de SHP1 Pyrheliometer

Contact us

If you are thinking of carrying out a project, would like to purchase any instrumentation type or would like more information about DILUS services, please leave your contact information. The team will contact you as soon as possible.SHP1 Pyrheliometer, leave your details. The team will contact you as soon as possible.



    Controller: DILUS INSTRUMENTACIÓN Y SISTEMAS S.A.
    Purpose: Collection of personal data to be able to respond to your request
    Legal Basis: Consent of the data subject
    Recipients: No data will be transferred to third parties, except when legally required and except to entities collaborating with DILUS INSTRUMENTACIÓN Y SISTEMAS S.A. for the provision of services and the correct management of the entity. In such cases, data will only be used for purposes and uses strictly necessary for the development of their activity and for which their services were required, and they may not use the data for any other purpose
    Rights: Access, rectify, or delete data, as well as other rights, as explained in the additional information in the privacy policy