Soil respiration

LI-7820N2O/H2O Trace Gas Analyzer

Add to budget
Imagen de: LI-7820N2O/H2O Trace Gas Analyzer

The LI-7820 N2O/H2Trace Gas Analyzer offers high-precision nitrous oxide measurements in a low power, portable design—enabling it to easily integrate into survey and long-term soil flux systems. Pair it with the LI-7810 CH4/CO2/H2Trace Gas Analyzer or LI-870 CO2/H2Analyzer for CO2 and CH4 measurements at your site.

A combination of several patented technologies with Optical Feedback-Cavity Enhanced Absorption Spectroscopy (OF-CEAS) results in precise and stable N2measurements, for chamber-based soil flux research.

LI-7820 Advantages

  • Connect to the Smart Chamber or the LI-8250 Multiplexer for collecting, processing and viewing N2fluxes on site or remotely
  • Functions with a low power, weatherized design that operates on hot-swappable, 8-hour batteries
  • Deploys long term with minimum infrastructure requirements (e.g., simple cover or stand) to create a user-friendly solution for lab and field measurements
  • Connects to a smartphone via Wi-Fi-enabled communications to monitor and view live data without a field computer and works with SoilFluxPro Software for dataset management

For details on the design and technology used in the LI-7820, visit the Trace Gas Analyzers page.

Preliminary Specifications


General


  • Measurement Technique: OF-CEAS (Optical Feedback-Cavity Enhanced Absorption Spectroscopy)
  • Measurement Rate: 1 sample per second (1 Hz)
  • Optical Cavity Volume: 6.41 cm3
  • Flow Rate: 250 sccm (nominally)
  • Total Weight: 10.5 kg (including batteries)
  • Case Dimensions: 51 cm L x 33 cm W x 18 cm H
  • Operating Temperature Range: –25 °C to 45 °C (without solar load, under normal operating conditions)
  • Operating Humidity Range: 0 to 85% RH (non-condensing, without solar load, under normal operating conditions)
  • Sample Line Humidity Range: 0 to 99.9% non-condensing
  • Operating Pressure Range: 70 to 110 kPa
  • Connectivity: Ethernet, Wi-Fi (not available in some countries)
  • Wi-Fi Compatibility: 2.4 GHz, 802.11 a/b/g/n/ac
  • Power Consumption:
    • Steady State Operation: 22 W at 25 °C
    • Warmup (10.5 to 33 VDC power supply, pins 3 and 4): Up to 100 W with batteries charging
    • Warmup (Universal power supply or 24 VDC power supply, pins 1 and 5): Up to 140 W with batteries charging
    • DC Power Source: 1.3 to 2.3 W (instrument powered off with batteries not charging)
  • Power Supply: Universal Power Adapter (Input: 100 to 240 VAC, 50-60 Hz; Output: 24 VDC)
  • Battery Life: 8 hours typical with 2 batteries

N2O Measurements


  • Measurement Range: 0 to 100 ppm
  • Response Time (T10-T90): N2O ≤ 2 seconds, 0 to 330 ppb
  • Precision (1σ):
    • 0.40 ppb at 330 ppb with 1 second averaging
    • 0.20 ppb at 330 ppb with 5 second averaging


H2O Measurements


  • Range: 0 to 60,000 ppm
  • Precision (1σ):
    • 45 ppm at 10,000 ppm with 1 second averaging
    • 20 ppm at 10,000 ppm with 5 second averaging
Imagen de LI-7820N2O/H2O Trace Gas Analyzer

Contact us

If you are thinking of carrying out a project, would like to purchase any instrumentation type or would like more information about DILUS services, please leave your contact information. The team will contact you as soon as possible.LI-7820N2O/H2O Trace Gas Analyzer, leave your details. The team will contact you as soon as possible.



    Dilus is 100% compliant with the General Data Protection Regulation (GDPR). For more information on how we collect, store and process your private information in accordance with GDPR, please see our privacy policy. This policy was last updated in January 2020.