- ISO 9060 spectrally flat Class A
- Excellent linearity
- Fast response time
- Low tilt error
- 5 year warranty
CMP11 Pyranometer
CMP11 uses the temperature compensated detector technology originally developed for the CMP22 and is a step up in performance from the CMP6. It is particularly suitable for meteorological networks and the reduced response time of 1.66 seconds (63%) meets the requirements for solar energy applications.
A waterproof socket is fitted for the signature yellow signal cable, which is available in a range of lengths pre-wired to the waterproof plug.
The integral bubble level is raised to the top of the housing and can be viewed without removing the redesigned snap-on sun shield, which also covers the connector. The connector with gold-plated contacts allows for easy exchange and re-calibration. The screw-in drying cartridge is easy to remove and the replacement desiccant is supplied in convenient refill packets.
The pyranometer does not require any power, it supplies a low voltage of 0 to 20 mV in relation to the amount of incoming radiation. When a higher voltage level or a 4 to 20 mA signal is required, the AMPBOX is the perfect solution.
Specifications
Spectral range (50% points) | 285 to 2800 nm |
Sensitivity | 7 to 14 µV/W/m² |
Response time | < 5 s |
Zero offset A | < 7 W/m² |
Zero offset B | < 2 W/m² |
Directional response (up to 80° with 1000 W/m² beam) | < 10 W/m² |
Temperature dependence of sensitivity (-10 ºC to +40 ºC) | < 1 % |
Operational temperature range | -40 °C to +80 °C |
Maximum solar irradiance | 4000 W/m² |
Field of view | 180 ° |
Documents
Technical Advise - Desiccant replacement interval
Pyranometer versus Reference Cell
KippZonen_Pyranometer_Calibrations_Infographic
Brochure - Solar Irradiance Monitoring in Solar Energy Projects
Brochure - Pyranometers - CMP series - French
Brochure - Pyranometers - CMP series - Spanish
Brochure - Pyranometers - CMP series - Russian
Brochure - Solar Monitoring Stations
Declaration of Conformity CMP11 Pyranometer
Instruction Sheet - Pyranometers - CMP-series
Datasheet - CMP10 - CMP11 - SMP10 - SMP11 - pyranometers - EN
Manual - Pyranometers - CMP series - English
Contact us
If you are thinking of carrying out a project, would like to purchase any instrumentation type or would like more information about DILUS services, please leave your contact information. The team will contact you as soon as possible.CMP11 Pyranometer, leave your details. The team will contact you as soon as possible.