The ultrasonic measurement principle allows, compared to the classic anemometers, an inertia-free measurement of running variable dimensions with highest precision and accuracy. It is especially suitable for the measurement of gust- and peak values.
The measurement values can be transmitted digitally and/or in analogue form.
The serial or analogue output of the data is carried out alternatively as instantaneous value or with selectable time frame.
If necessary, the sensor arms are automatically heated in case of critical ambient emperatures. The possibility of malfunction, caused by icing, is minimized.
Model no. 4.3820.3x.xxx, thanks to the additionally installed ultrasonic converter heating, is suitable even for the more difficult use in locations where frequently icing is to be expected
Specification
Part number: 4.382x.4x.xxx
Wind speed
|
|
Measuring range
|
0 … 85 m/s
|
Resolution
|
0.1 m/s (standard)
0.01 m/s (user defined) |
Accuracy
|
±0.1 m/s rms ( < 5 m/s )
±2 % rms ( 5 … 85 m/s ) |
Wind direction
|
|
Measuring range
|
0 … 360 °
|
Resolution
|
1 °
1 ° (standard) < 1 ° (user defined) |
Accuracy
|
±1 ° @ WS 1 … 60 m/s
±2 ° @ WS 60 … 85 m/s |
Virtual temp.
|
|
Measuring range
|
-50 … +80 °C
|
Resolution
|
0.1 K
|
Accuracy
|
±0.5 K @ WS < 35 m/s
|
Data output digital
|
|
Interface
|
RS485 / RS422
|
Baudrate
|
1200 … 921600 Baud
|
Data values
|
instant. values, average values, standard deviation
|
Output range
|
1 per 10 msec up to
1 per 60 sec |
Status signals
|
heating, Meas section error, Temperature of meas section
|
Data output analog
|
|
Wind speed
|
0 … 20 mA
4 … 20 mA 0 … 10 V 2 … 10 V |
Stromausgang
|
max. 400 Ω
|
Wind direction
|
0 … 20 mA
4 … 20 mA 0 … 10 V 2 … 10 V |
Voltage output
|
min. 4000 Ω
|
Resolution
|
16 bit
|
Data input analog (alternative)
|
|
Chanels
|
3
|
Resolution
|
16bit
|
Operating voltage
|
|
Electronic
|
8 … 78 V DC or
12 … 55 V AC / 2.5 W |
Heating
|
48 V AC/DC, typ 280 W
|
General
|
|
Bus operation
|
up to 98 sensors
|
Electr. connection
|
8 pol. connector
|
Mounting
|
on a mast tube 1,5«
|
Housing
|
stainless steel (V4A) AiSi316Ti
|
Protection
|
IP 67
|
Dimension
|
Ø 424 mm x 287 mm
|
Weight
|
2.5 kg
|
Documentos
Contáctenos
Si está pensando en llevar a cabo un proyecto, desea adquirir instrumentación, quiere más información al respecto de los servicios de DILUS o desea mas información sobre Ultrasonic Anemometer 2D, deje sus datos. El equipo se pondrá en contacto con usted a la mayor brevedad posible.